{"title":"Digital Earth Clamp Meter","description":null,"products":[{"product_id":"digital-earth-clamp-tester-dect9-2","title":"Digital Earth Clamp Tester DECT9+","description":"\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLong Jaw size: 65mm x 32mm. The unique long Jaw is particularly suitable where grounding is done by flat steel or copper strips.\u003c\/li\u003e\n\u003cli\u003eRange: 0.01Ω to 1500 Ω, leakage current: 0.00mA to 30A\u003c\/li\u003e\n\u003cli\u003eMaximum Resistance Measurement Resolution 0.001 Ω.\u003c\/li\u003e\n\u003cli\u003eDisplay 4 Digits LCD, 47×28.5 mm in length.\u003c\/li\u003e\n\u003cli\u003eUSB Communication Port\u003c\/li\u003e\n\u003cli\u003eOver range (OL Ω) as well as low range (L0.01 Ω) indication.\u003c\/li\u003e\n\u003cli\u003eLow bat indication and Data hold facility, Jaw opening Indication, Noise signal\u003c\/li\u003e\n\u003cli\u003eDouble insulation level and also protected from External magnetic as well as Electric field.\u003c\/li\u003e\n\u003cli\u003eExternal Magnetic field: \u0026lt;40A\/m\u003c\/li\u003e\n\u003cli\u003eExternal Magnetic field: \u0026lt;1V\/m\u003c\/li\u003e\n\u003cli\u003eAutomatic range selection \u0026amp; Automatic Self Calibration.\u003c\/li\u003e\n\u003cli\u003eAlarm with measured value\u003c\/li\u003e\n\u003cli\u003eSingle Measuring Time: 0.5 second.\u003c\/li\u003e\n\u003cli\u003eData Storage: 99 Groups\u003c\/li\u003e\n\u003cli\u003eClamp Jaw opening Size: 32mm\u003c\/li\u003e\n\u003cli\u003eSetting Range of Resistance Alarm Critical Value: 1-199 Ω\u003c\/li\u003e\n\u003cli\u003eSetting Range of Current Alarm Critical Value: 1-499mA\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -10˚C to 55˚C\u003c\/li\u003e\n\u003cli\u003ePower: 6 VDC (AA 1.5V x 4)\u003c\/li\u003e\n\u003cli\u003eDimensions: 285mm X 85mm X 56mm\u003c\/li\u003e\n\u003cli\u003eWeight: 1100gms (including Batteries).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e\u003cu\u003eSPECIFICATION:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003cu\u003e \u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eRanges and Accuracy at [ (20 ±3˚C) 50% RH ± 10%]\u003c\/p\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRanges\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e0.010 – 0.099Ω\u003c\/td\u003e \u003ctd\u003e0.001Ω\u003c\/td\u003e \u003ctd\u003e±(1%+0.01Ω)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e0.10 – 0.99Ω\u003c\/td\u003e \u003ctd\u003e0.01Ω\u003c\/td\u003e \u003ctd\u003e± (1% + 0.01Ω)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e1.0 -49.9Ω\u003c\/td\u003e \u003ctd\u003e0.01Ω\u003c\/td\u003e \u003ctd\u003e± (1.0% + 0.1Ω)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e50.0 – 99.5Ω\u003c\/td\u003e \u003ctd\u003e0.5Ω\u003c\/td\u003e \u003ctd\u003e± (1.5% + 0.5Ω)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e100-199Ω\u003c\/td\u003e \u003ctd\u003e1Ω\u003c\/td\u003e \u003ctd\u003e± (2% + 1Ω)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e200- 395Ω\u003c\/td\u003e \u003ctd\u003e5Ω\u003c\/td\u003e \u003ctd\u003e± (5% + 5Ω)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e400- 590 Ω\u003c\/td\u003e \u003ctd\u003e10 Ω\u003c\/td\u003e \u003ctd\u003e± (10% + 10Ω)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e600 – 880 Ω\u003c\/td\u003e \u003ctd\u003e20 Ω\u003c\/td\u003e \u003ctd\u003e± (20% + 20Ω)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e900 – 1500 Ω\u003c\/td\u003e \u003ctd\u003e30 Ω\u003c\/td\u003e \u003ctd\u003e± (25% + 30Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eRanges and Accuracy of current measurement: \u003c\/strong\u003e\u003c\/p\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e0.00mA-9.95mA\u003c\/td\u003e \u003ctd\u003e0.05mA\u003c\/td\u003e \u003ctd\u003e±2.5%+1mA\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e10mA-99mA\u003c\/td\u003e \u003ctd\u003e0.1mA\u003c\/td\u003e \u003ctd\u003e±2.5%+5mA\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e100mA-300mA\u003c\/td\u003e \u003ctd\u003e1mA\u003c\/td\u003e \u003ctd\u003e±2.5%+10mA\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e0.30A-2.99A\u003c\/td\u003e \u003ctd\u003e0.01A\u003c\/td\u003e \u003ctd\u003e±2.5%+0.1A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e3.0A-9.9A\u003c\/td\u003e \u003ctd\u003e0.1A\u003c\/td\u003e \u003ctd\u003e±2.5%+0.3A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e10A-20A\u003c\/td\u003e \u003ctd\u003e0.1A\u003c\/td\u003e \u003ctd\u003e±2.5%+0.5A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e10A-30A\u003c\/td\u003e \u003ctd\u003e0.1A\u003c\/td\u003e \u003ctd\u003e±3.0%+1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003e\u003cstrong\u003e\u003cu\u003e \u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eMEXTECH’s Digital Earth Clamp Tester DECT9+ is designed for grounding resistance measurement across power, telecommunications, meteorology, oilfield, construction, electrical equipment and industrial applications. It also measures leakage current, grounding system current, and neutral current.\u003c\/p\u003e\u003ch3\u003eAccessories\u003c\/h3\u003e\u003cp\u003eCarrying Case, Standard Loop Resistance of 5.1Ω, Instruction Manual, Batteries, USB Communication, Cable and Software.\u003c\/p\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1058\/7003\/3239\/files\/EARTH-CLAMP-TESTER-DECT9-1.pdf?v=1792744647\" target=\"_blank\" rel=\"noopener\"\u003eCatalog (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Mextech","offers":[{"title":"Default Title","offer_id":52809510453464,"sku":null,"price":35789.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0848\/6653\/1544\/files\/DECT9-scaled.jpg?v=1793820030"},{"product_id":"digital-earth-clamp-meter-model-dect-9am-2","title":"Digital Earth Clamp Meter DECT2","description":"\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLong Jaw size: 55mm x 32mm. The unique long Jaw is particularly suitable where grounding is done by flat steel or copper strips.\u003c\/li\u003e\n\u003cli\u003eRange: 0.01Ω to 200Ω\u003c\/li\u003e\n\u003cli\u003eMaximum Resistance Measurement Resolution 0.001Ω.\u003c\/li\u003e\n\u003cli\u003eData Storage: 99 Groups.\u003c\/li\u003e\n\u003cli\u003eAlarm Critical Values setting Range: Resistance: 1 ~ 199Ω\u003c\/li\u003e\n\u003cli\u003eDisplay 4 Digits LCD, 47×28.5 mm in length.\u003c\/li\u003e\n\u003cli\u003eOver range (OL Ω) as well as low range (L0.01Ω) indication.\u003c\/li\u003e\n\u003cli\u003eLow bat indication and Data hold facility, Jaw opening Indication, Noise signal\u003c\/li\u003e\n\u003cli\u003eDouble insulation level and also protected from External magnetic as well as Electric field.\u003c\/li\u003e\n\u003cli\u003eExternal Magnetic field: \u0026lt;40A\/m\u003c\/li\u003e\n\u003cli\u003eExternal Magnetic field: \u0026lt;1V\/m\u003c\/li\u003e\n\u003cli\u003eAutomatic range selection \u0026amp; Automatic Self Calibration.\u003c\/li\u003e\n\u003cli\u003eAlarm with measured value\u003c\/li\u003e\n\u003cli\u003eSingle Measuring Time: 1 second.\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -20˚C to 55˚C, 10% RH – 90% RH\u003c\/li\u003e\n\u003cli\u003ePower: 1.5V x 4 Batteries\u003c\/li\u003e\n\u003cli\u003eDimensions: 275mm X 85mm X 56mm (Approx.).\u003c\/li\u003e\n\u003cli\u003eNet Weight: Approx. 850g.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eP\u003c\/li\u003e\u003c\/ul\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRanges\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e0.010 – 0.099Ω\u003c\/td\u003e \u003ctd\u003e0.001Ω\u003c\/td\u003e \u003ctd\u003e±(1%+0.01Ω)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e0.10 – 0.99Ω\u003c\/td\u003e \u003ctd\u003e0.01Ω\u003c\/td\u003e \u003ctd\u003e± (1% + 0.01Ω)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e1.0 -49.9Ω\u003c\/td\u003e \u003ctd\u003e0.1Ω\u003c\/td\u003e \u003ctd\u003e± (1% + 0.1Ω)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e50.0 – 99.5Ω\u003c\/td\u003e \u003ctd\u003e0.5Ω\u003c\/td\u003e \u003ctd\u003e± (1.5% + 0.5Ω)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e100-200Ω\u003c\/td\u003e \u003ctd\u003e1Ω\u003c\/td\u003e \u003ctd\u003e± (2% + 1Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eOverview\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMeasures Earth Resistance at electrical ground rod and grid.\u003c\/li\u003e \u003cli\u003eUse for testing quality of grounding without disconnecting the ground rod under test.\u003c\/li\u003e \u003cli\u003eConduct field surveys fast and effectively and retrieve and analyze readings at a later time.\u003c\/li\u003e \u003cli\u003eUse on telecommunication Tower’s grounding.\u003c\/li\u003e \u003cli\u003eUseful in finding earth fault such as discontinuation or loose contact of earthling strips or cables.\u003c\/li\u003e \u003cli\u003eTo find the resistance of earth pit.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eAccessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCarrying Case,\u003c\/li\u003e \u003cli\u003eStandard Test Ring Resistance of 1Ω,\u003c\/li\u003e \u003cli\u003eInstruction Manual,\u003c\/li\u003e \u003cli\u003eBatteries\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1058\/7003\/3239\/files\/EARTH-CLAMP-TESTER-DECT2.pdf?v=1792744636\" target=\"_blank\" rel=\"noopener\"\u003eCatalog (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Mextech","offers":[{"title":"Default Title","offer_id":52809511895256,"sku":null,"price":19116.0,"currency_code":"INR","in_stock":true}]}],"url":"https:\/\/mextechin.com\/collections\/digital-earth-clamp-meter.oembed","provider":"Mextech Technologies India Private Limited","version":"1.0","type":"link"}