{"title":"Digital Earth Tester","description":null,"products":[{"product_id":"cem-dt-5300b-digital-earth-resistance-tester","title":"CEM DT-5300B Digital Earth Resistance Tester","description":"\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eIt is designed for measurement of the resistance of earthen used in the electrical equipment as well as for measurement of ground resistivity. It can be used for measurements of the other low regular and liquid resistances. It can also be used for measurement of voltage AC, voltage DC and earth voltage. This instrument finds wide application for testing earthen installation in power based industries, telecommunication networks and electrical traction systems etc\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth resistance range\u003c\/td\u003e \u003ctd\u003e20W, 200W, 2000W\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e \u003ctd\u003eLarge LCD with dual display\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eMultimeter function Range\u003c\/td\u003e \u003ctd\u003e200kW, 750VAC, 1000VDC\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e \u003ctd\u003e2.5 times per second\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eZero Adjustment\u003c\/td\u003e \u003ctd\u003eAutomatic adjustment\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eOver Range Indicator\u003c\/td\u003e \u003ctd\u003eNumber 1 of highest digit is displayed.\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eLow Battery Indication\u003c\/td\u003e \u003ctd\u003eThe is displayed when the battery Voltage drop below the operating voltage\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e \u003ctd\u003eAuto Power Off\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e \u003ctd\u003e0ºC to 40ºC (32ºF to 104ºF) and Humidity below 80% RH\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e \u003ctd\u003e-10ºC to 60ºC (14ºF to 140ºF) and Humidity below 70% RH\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePower source\u003c\/td\u003e \u003ctd\u003e6×1.5V Size “AA” battery or Equivalent (DC9V)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e \u003ctd\u003e200(L) x 92(W) x 50(H) mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e \u003ctd\u003eApprox 700g include battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003eAccuracies are specified in the way:\u003c\/p\u003e \u003cp\u003e±(…% of reading +…digits) at 23ºC ±5ºC, below 80% RH.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eEarth\u003c\/strong\u003e \u003cstrong\u003eresistance\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e20W\u003c\/td\u003e \u003ctd\u003e0.01W\u003c\/td\u003e \u003ctd\u003e±(2%+10d)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e200W\u003c\/td\u003e \u003ctd\u003e0.1W\u003c\/td\u003e \u003ctd\u003e±(2%+3d)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e2000W\u003c\/td\u003e \u003ctd\u003e1W\u003c\/td\u003e \u003ctd\u003e±(2%+3d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eEarth voltage\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e200V\u003c\/td\u003e \u003ctd\u003e0.1V\u003c\/td\u003e \u003ctd\u003e±(3%+3d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eOHMS\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e200kW\u003c\/td\u003e \u003ctd\u003e0.1kW\u003c\/td\u003e \u003ctd\u003e±(1%+2d)\u003c\/td\u003e \u003ctd\u003e250Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eDC Voltage\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e1000V\u003c\/td\u003e \u003ctd\u003e1V\u003c\/td\u003e \u003ctd\u003e±(0.8%+3d)\u003c\/td\u003e \u003ctd\u003e10MW\u003c\/td\u003e \u003ctd\u003e1000Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eAC Voltage\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e750V\u003c\/td\u003e \u003ctd\u003e1V\u003c\/td\u003e \u003ctd\u003e±(1.2%+10d)\u003c\/td\u003e \u003ctd\u003e10MW\u003c\/td\u003e \u003ctd\u003e750Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eIt can be used for measurements of the other low regular and liquid resistances. It can also be used for measurement of voltage AC, voltage DC and earth voltage. This instrument finds wide application for testing earthen installation in power based industries, telecommunication networks and electrical traction systems etc\u003c\/p\u003e\u003ch3\u003eAccessories\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e\u003cu\u003eACCESSORIES:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eBatteries, Instruction Manual, Test Leads, Spikes, Cables, Hard Carrying Case, Test Certificate and Test Certificate.\u003c\/p\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1058\/7003\/3239\/files\/DT-5300B-DIGITAL-EARTH-RESISTANCE-TESTER.pdf?v=1792744635\" target=\"_blank\" rel=\"noopener\"\u003eCatalog (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"CEM","offers":[{"title":"Default Title","offer_id":52809507930328,"sku":null,"price":9558.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0848\/6653\/1544\/files\/New-Project-6.jpg?v=1793013163"},{"product_id":"cem-dt-5300-digital-earth-resistance-tester","title":"CEM DT-5300 Digital Earth Resistance Tester","description":"\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eIt is designed for measurement of the resistance of earthen used in the electrical equipment as well as for measurement of ground resistivity. It can be used for measurements of the other low regular and liquid resistances. It can also be used for measurement of voltage AC, voltage DC and earth voltage. This instrument finds wide application for testing earthen installation in power based industries, telecommunication networks and electrical traction systems etc\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth resistance range\u003c\/td\u003e \u003ctd\u003e10W,100W,1000W\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e \u003ctd\u003eLarge LCD with dual display\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eMultimeter function Range\u003c\/td\u003e \u003ctd\u003e200kW, 750VAC, 1000VDC\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e \u003ctd\u003e2.5 times per second\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eZero Adjustment\u003c\/td\u003e \u003ctd\u003eAutomatic adjustment\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eOver Range Indicator\u003c\/td\u003e \u003ctd\u003eNumber 1 of highest digit is displayed.\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eLow Battery Indication\u003c\/td\u003e \u003ctd\u003eThe is displayed when the battery Voltage drop below the operating voltage\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e \u003ctd\u003eAuto Power Off\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e \u003ctd\u003e0ºC to 40ºC (32ºF to 104ºF) and Humidity below 80% RH\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e \u003ctd\u003e-10ºC to 60ºC (14ºF to 140ºF) and Humidity below 70% RH\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePower source\u003c\/td\u003e \u003ctd\u003e6×1.5V Size “AA” battery or Equivalent (DC9V)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e \u003ctd\u003e200(L) x 92(W) x 50(H) mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e \u003ctd\u003eApprox 700g include battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003eAccuracies are specified in the way:\u003c\/p\u003e \u003cp\u003e±(…% of reading +…digits) at 23ºC ±5ºC, below 80% RH.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eEarth\u003c\/strong\u003e \u003cstrong\u003eresistance\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e10W\u003c\/td\u003e \u003ctd\u003e0.01W\u003c\/td\u003e \u003ctd\u003e±(2%+10d)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e100W\u003c\/td\u003e \u003ctd\u003e0.1W\u003c\/td\u003e \u003ctd\u003e±(2%+3d)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e1000W\u003c\/td\u003e \u003ctd\u003e1W\u003c\/td\u003e \u003ctd\u003e±(2%+3d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eEarth voltage\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e200V\u003c\/td\u003e \u003ctd\u003e0.1V\u003c\/td\u003e \u003ctd\u003e±(3%+3d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eOHMS\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e200kW\u003c\/td\u003e \u003ctd\u003e0.1kW\u003c\/td\u003e \u003ctd\u003e±(1%+2d)\u003c\/td\u003e \u003ctd\u003e250Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eDC Voltage\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e1000V\u003c\/td\u003e \u003ctd\u003e1V\u003c\/td\u003e \u003ctd\u003e±(0.8%+3d)\u003c\/td\u003e \u003ctd\u003e10MW\u003c\/td\u003e \u003ctd\u003e1000Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eAC Voltage\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e750V\u003c\/td\u003e \u003ctd\u003e1V\u003c\/td\u003e \u003ctd\u003e±(1.2%+10d)\u003c\/td\u003e \u003ctd\u003e10MW\u003c\/td\u003e \u003ctd\u003e750Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eIt is designed for measurement of the resistance of earthen used in the electrical equipment as well as for measurement of ground resistivity. It can be used for measurements of the other low regular and liquid resistances. It can also be used for measurement of voltage AC, voltage DC and earth voltage. This instrument finds wide application for testing earthen installation in power based industries, telecommunication networks and electrical traction systems etc\u003c\/p\u003e\u003ch3\u003eAccessories\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e\u003cu\u003eACCESSORIES:\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eBatteries, Instruction Manual, Test Leads, Spikes, Cables, Hard Carrying Case, Test Certificate and Test Certificate.\u003c\/p\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1058\/7003\/3239\/files\/DT-5300-DIGITAL-EARTH-RESISTANCE-TESTER.pdf?v=1792744572\" target=\"_blank\" rel=\"noopener\"\u003eCatalog (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"CEM","offers":[{"title":"Default Title","offer_id":52809507963096,"sku":null,"price":8496.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0848\/6653\/1544\/files\/New-Project-6_fe3e0d12-9ea3-4fe3-9bc0-a37a44645980.jpg?v=1793013164"},{"product_id":"digital-earth-resistance-tester-det-99c","title":"Digital Earth Resistance Tester DET-99C","description":"\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRugged ABS body\u003c\/li\u003e\n\u003cli\u003eEasy to use hand held meter\u003c\/li\u003e\n\u003cli\u003eFour terminals E1, P1, P2, E2\u003c\/li\u003e\n\u003cli\u003eLow battery indication\u003c\/li\u003e\n\u003cli\u003eEarth Resistance \u0026amp; Earth Resistivity Function\u003c\/li\u003e\n\u003cli\u003eTechnical Details: Display: 3½ Digits, LCD\u003c\/li\u003e\n\u003cli\u003ePower supply: 8 x 1.2V Rechargeable cells with 230V AC adopter\u003c\/li\u003e\n\u003cli\u003eDimensions (in mm): 139 x 97 x 49 mm (Approx.)\u003c\/li\u003e\n\u003cli\u003eWeight: 575 gm (Approx.)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cp\u003eMeasuring Range 0 – 1000 ῼ (10 ῼ, 1000 ῼ)\u003c\/p\u003e\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003e‘MEXTECH’ Digital Earth Resistance Tester is designed to measure the resistance if earth used in\u003cbr\u003epower circuit, Telecommunications, Railway Electrification, Domestic and Industrial electrical\u003cbr\u003einstallations. The tester measures directly the resistance of the earth andalso measure the ground\u003cbr\u003eresistivity. The study, elegant and compact body makes the instrument portable, easy to use, Handheld\u003cbr\u003einstrument.\u003c\/p\u003e\u003ch3\u003eAccessories\u003c\/h3\u003e\u003cp\u003eStandard Accessories :\u003cbr\u003e(i) Carrying Case (ii) Instruction Manual (iii) 8pcs 1.2V Batteries + Battery charger\u003cbr\u003eOptional Accessories :\u003cbr\u003e(at extra cost) :\u003cbr\u003e• 4 Nos. M. S. Spike (18 Inch Length) • 1 Nos. Hammer • 4 Nos. Cable (25 feet) • 1 Nos. Screwdriver, all\u003cbr\u003epacked in one earth testing kit bag\u003c\/p\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1058\/7003\/3239\/files\/DET99C-NEW.pdf?v=1792744638\" target=\"_blank\" rel=\"noopener\"\u003eCatalog (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Mextech","offers":[{"title":"Default Title","offer_id":52809509273816,"sku":null,"price":4248.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0848\/6653\/1544\/files\/digital-earth-resistance-tester-det-99c-2026-1.png?v=1793815905"},{"product_id":"digital-earth-tester-det1620","title":"Digital Earth Tester DET1620","description":"\u003cp\u003eEarth resistance measurement for grounds and pits.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e2\/3\/4-pole measurement for earth resistance, soil resistivity, earth voltage\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eDC 9V( Alkaline dry battery LR14 1.5VX 6 PCS )\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e \u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e \u003ctd\u003eEarth Resistance: 0.00Ω~30.00kΩ\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\u003ctd\u003eSoil Resistivity: 0.00Ωm~9000kΩm\u003c\/td\u003e\u003c\/tr\u003e \u003ctr\u003e\u003ctd\u003eEarth Voltage: 0V~600V\u003c\/td\u003e\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Mode\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePrecise 4-pole measurement, 3-pole measurement, simple 2-pole measurement of earth resistance\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e \u003c\/strong\u003e \u003cp\u003e\u003cstrong\u003eMeasurement Method\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e \u003ctd\u003eEarth Resistance: rated current change-pole method, test current 20mA Max \u003cp\u003eSoil Resistivity: 4-pole method (Wenner method)\u003c\/p\u003e \u003cp\u003eEarth Voltage: average rectification(between P(S)-ES)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e \u003cstrong\u003eFrequency\u003c\/strong\u003e\n\u003c\/td\u003e \u003ctd\u003e128Hz\/111Hz\/105Hz\/94Hz(AFC)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e \u003cstrong\u003eCurrent\u003c\/strong\u003e\n\u003c\/td\u003e \u003ctd\u003e\u0026gt;20mA (sine wave)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOpen-circuit\u003c\/strong\u003e \u003cstrong\u003eTest\u003c\/strong\u003e \u003cstrong\u003eCurrent\u003c\/strong\u003e\n\u003c\/td\u003e \u003ctd\u003eAC 40V max\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e \u003cstrong\u003eVoltage\u003c\/strong\u003e \u003cstrong\u003eWave\u003c\/strong\u003e\n\u003c\/td\u003e \u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eElectrode\u003c\/strong\u003e \u003cstrong\u003eDistance\u003c\/strong\u003e\u003cstrong\u003e Range\u003c\/strong\u003e\n\u003c\/td\u003e \u003ctd\u003eCan be set 1m~100m\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e \u003cp\u003e\u003cstrong\u003eShift\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e \u003ctd\u003eEarth resistance: 0.00Ω~30.00kΩ automatic shift\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\u003ctd\u003eSoil Resistivity: 0.00Ωm~9000kΩm automatic shift\u003c\/td\u003e\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBacklight\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eControllable white screen backlight, suitable for dim places\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Mode\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e4-digital super-large LCD display, white screen backlight\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Indication\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eDuring measurement, LED flash indicator, LCD count down display, progress bar indicator\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLCD Frame Dimension\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e128mmX75mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLCD Display Dimension\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e124mmX67mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeter Dimension\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e212mm(L)X175mm(W)X85mm(H)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Time\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eEarth Voltage: about 3 times\/second\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eEarth resistance, soil resistivity: about 15 seconds\/time\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Times\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eOver 5000 times (Short-circuit test, interval time should be at least 30 seconds)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Voltage\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ebelow AC 600V measure\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eUSB interface, software monitoring, storage data can be \u003cp\u003euploaded to computer, saved or printed.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Cable\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e1PCS USB communication cable, length 1.5m\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e300 groups, “MEM” symbol storage indicator, flash display “FULL” symbol indicate storage full\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Hold\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eData hold function: “HOLD” symbol display\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Read\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eData read function: “READ” symbol display\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverflow Display\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eOver range overflow function: “OL” symbol display\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterference Test\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eRecognize interference signal automatically, “NOISE” \u003cp\u003esymbol display when interference voltage exceed 5V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Ground Test\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eWith auxiliary earth resistance test function, 0.00KΩ~30KΩ \u003cp\u003e(100R+rC\u0026lt;50kΩ, 100R+rP\u0026lt;50kΩ)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Function\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eMeasurement value exceeds alarm setting value, will “DU–DU–DU–” alarm hint\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e \u003c\/strong\u003e \u003cp\u003e\u003cstrong\u003eBattery Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e \u003ctd\u003eWhile battery voltage decreases to around 7.5V, will display battery voltage low symbol“ ”, and reminding to replace \u003cp\u003ethe battery\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e \u003c\/strong\u003e \u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eWorking Current\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e \u003ctd\u003eStandby: about 20mA (Backlight close)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eBoot up and open backlight: about 45mA (25mA backlight close)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eMeasurement: about 100mA (Backlight close)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e \u003c\/strong\u003e \u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e \u003ctd\u003eTester: 1330g\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eTotal weight: about 2.15kg (include package)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eWorking Temperature \u0026amp;\u003c\/strong\u003e \u003cp\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e \u003ctd\u003e-10℃~40℃, below 80%RH\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage temperature \u0026amp; humidity\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e-20℃~60℃, below 70%RH\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eMeasuring earth resistance: between each interfaces of \u003cp\u003eC(H)-E, P(S)-ES, AC 280V\/3 seconds\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eOver 20MΩ (between circuit and enclosure it is 500V)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand Voltage\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAC 3700V\/rms (Between circuit and enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectromagnetic Features\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eIEC61326(EMC)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e \u003c\/strong\u003e \u003cp\u003e\u003cstrong\u003eSuitable Safety Standard\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e \u003ctd\u003eIEC61010-1 (CAT Ⅲ 300V, CAT IV 150V, Pollution 2), \u003cp\u003eIEC61010-031, IEC61557-1 (Earth resistance), IEC61557-5\u003c\/p\u003e \u003cp\u003e(Soil resistivity), JJG 366-2004\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInfluence Constant\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eBase Condition\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eWorking Conditions\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eRemark\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temp\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e23℃±1℃\u003c\/td\u003e \u003ctd\u003e-10℃~40℃\u003c\/td\u003e \u003ctd\u003e—-\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Humidity\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e40%~60%\u003c\/td\u003e \u003ctd\u003e＜80%\u003c\/td\u003e \u003ctd\u003e—-\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking Voltage\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e9V±0.1V\u003c\/td\u003e \u003ctd\u003e9V±1.5V\u003c\/td\u003e \u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eAuxiliary Earth Resistance\u003c\/strong\u003e \u003cp\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e \u003ctd\u003e＜100Ω\u003c\/td\u003e \u003ctd\u003e＜30kΩ\u003c\/td\u003e \u003ctd\u003erC, rP\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterference Voltage\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNon\u003c\/td\u003e \u003ctd\u003e＜20V\u003c\/td\u003e \u003ctd\u003e—-\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterference Current\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNon\u003c\/td\u003e \u003ctd\u003e＜2A\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrode Distance of measuring R\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ea＞5d\u003c\/td\u003e \u003ctd\u003ea＞5d\u003c\/td\u003e \u003ctd\u003e—-\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrode Distance of measuring ρ\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ea＞20h\u003c\/td\u003e \u003ctd\u003ea＞20h\u003c\/td\u003e \u003ctd\u003e—-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003ch2\u003e\u003cu\u003eIntrinsic error and performance indicators under base conditions\u003c\/u\u003e\u003c\/h2\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eMeasurement\u003c\/strong\u003e \u003cp\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e \u003cp\u003e\u003cstrong\u003eEarth Resistance (R)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e \u003ctd\u003e0.00Ω~30.00Ω\u003c\/td\u003e \u003ctd\u003e±2%rdg±3dgt\u003c\/td\u003e \u003ctd\u003e0.01Ω\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e30.0Ω~300.0Ω\u003c\/td\u003e \u003ctd\u003e±2%rdg±3dgt\u003c\/td\u003e \u003ctd\u003e0.1Ω\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e300Ω~3000Ω\u003c\/td\u003e \u003ctd\u003e±2%rdg±3dgt\u003c\/td\u003e \u003ctd\u003e1Ω\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e3.00kΩ~30.00kΩ\u003c\/td\u003e \u003ctd\u003e±4%rdg±3dgt\u003c\/td\u003e \u003ctd\u003e10Ω\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e \u003cp\u003e\u003cstrong\u003eSoil\u003c\/strong\u003e \u003cstrong\u003eResistivity\u003c\/strong\u003e\u003cstrong\u003e (ρ)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e \u003ctd\u003e0.00Ωm~99.99Ωm\u003c\/td\u003e \u003ctd rowspan=\"6\"\u003e(ρ=2πaR \u003cstrong\u003ea\u003c\/strong\u003e:1 m~100m; π=3.14)\u003c\/td\u003e \u003ctd\u003e0.01Ωm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e100.0Ωm~999.9Ωm\u003c\/td\u003e \u003ctd\u003e0.1Ωm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e1000Ωm~9999Ωm\u003c\/td\u003e \u003ctd\u003e1Ωm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e10.00kΩm~99.99kΩm\u003c\/td\u003e \u003ctd\u003e10Ωm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e100.0kΩm~999.9kΩm\u003c\/td\u003e \u003ctd\u003e100Ωm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e1000kΩm~9000kΩm\u003c\/td\u003e \u003ctd\u003e1kΩm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth Voltage\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAC 0.0~600V\u003c\/td\u003e \u003ctd\u003e±2%rdg±3dgt\u003c\/td\u003e \u003ctd\u003e0.1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eNote: 1. rC \u003c\/strong\u003emax or \u003cstrong\u003erP \u003c\/strong\u003emax, additional error≤±3%rdg±5dgt. (\u003cstrong\u003erC \u003c\/strong\u003emax: 4kΩ+100\u003cstrong\u003eR\u003c\/strong\u003e＜50kΩ, \u003cstrong\u003erP \u003c\/strong\u003emax: 4kΩ+100\u003cstrong\u003eR\u003c\/strong\u003e＜50kΩ)\u003c\/p\u003e \u003col\u003e\u003cli\u003eInterference voltage with 5V, additional error≤±5%rdg±5dgt.\u003c\/li\u003e\u003c\/ol\u003e \u003cp\u003e\u003cstrong\u003eWarning: \u003c\/strong\u003eVoltage measurement is strictly prohibited when the instrument is charged, connected to a computer, or supplied with external power\u003c\/p\u003e\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis earth tester is suitable for:\u003c\/p\u003e \u003cul\u003e\n\u003cli\u003e\u003cp\u003eElectrical contractors\u003c\/p\u003e\u003c\/li\u003e \u003cli\u003e\u003cp\u003eIndustrial maintenance teams\u003c\/p\u003e\u003c\/li\u003e \u003cli\u003e\u003cp\u003ePower distribution systems\u003c\/p\u003e\u003c\/li\u003e \u003cli\u003e\u003cp\u003eCommercial building electrical audits\u003c\/p\u003e\u003c\/li\u003e \u003cli\u003e\u003cp\u003eEarthing system installation \u0026amp; verification\u003c\/p\u003e\u003c\/li\u003e \u003cli\u003e\u003cp\u003eLightning protection systems\u003c\/p\u003e\u003c\/li\u003e \u003cli\u003e\u003cp\u003eSubstations and transformer grounding\u003c\/p\u003e\u003c\/li\u003e \u003cli\u003e\u003cp\u003eTelecommunication towers\u003c\/p\u003e\u003c\/li\u003e \u003cli\u003e\u003cp\u003eRenewable energy installations (solar\/wind)\u003c\/p\u003e\u003c\/li\u003e \u003cli\u003e\u003cp\u003eResidential electrical safety checks\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003eWherever earthing is essential, the DET1620 provides reliable and precise measurement.\u003c\/p\u003e \u003cp\u003eDET-1620 Earth Resistance Soil Resistivity Tester is specially designed and manufactured for on-site measurement of grounding resistance, soil resistivity, grounding voltage, grounding line leakage current, alternating current, and DC resistance. Apply digital processing technology, precision 4-wire method, 3-wire method and simple 2-wire method to measure grounding resistance; Adopt FFT (fast Fourier transform) technology, AFC (automatic frequency control) technology, automatic identification of interference and selection of measurement frequency, to minimize the impact of interference, provide more accurate grounding resistance value. With unique anti-interference ability and environmental adaptability, high repeated test consistency, ensuring high precision, high stability and high reliability for a long-term measurement.\u003c\/p\u003e\u003ch3\u003eAccessories\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTester\u003c\/td\u003e \u003ctd\u003e1 PC\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eMeter Case\u003c\/td\u003e \u003ctd\u003e1 PC\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eUSB Communication Cable\u003c\/td\u003e \u003ctd\u003e1 PCS\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eBatteries LR14 1.5V\u003c\/td\u003e \u003ctd\u003e6 PCS\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eManual\u003c\/td\u003e \u003ctd\u003e1 SET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1058\/7003\/3239\/files\/DIGITAL-EARTH-TESTER-DET1620.pdf?v=1792744642\" target=\"_blank\" rel=\"noopener\"\u003eCatalog (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1058\/7003\/3239\/files\/DET-1620-Manual-20250425.pdf?v=1792744648\" target=\"_blank\" rel=\"noopener\"\u003eManual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mextech","offers":[{"title":"Default Title","offer_id":52809511272664,"sku":"DET1620","price":42480.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0848\/6653\/1544\/files\/New-Project-60.jpg?v=1793013244"}],"url":"https:\/\/mextechin.com\/collections\/digital-earth-tester\/industry-automobile.oembed","provider":"Mextech Technologies India Private Limited","version":"1.0","type":"link"}