{"product_id":"digital-solar-true-rms-clamp-meter-dt4545","title":"Digital Solar True RMS Clamp Meter DT4545PRO","description":"\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDisplay: 5999 count LCD display\u003c\/li\u003e\n\u003cli\u003eNCV and DATA HOLD\u003c\/li\u003e\n\u003cli\u003eOperating temperature and humidity: 0–40C (\u0026lt;80% RH; not applicable below 10C.)\u003c\/li\u003e\n\u003cli\u003eStorage temperature and humidity: -10C to 50C (\u0026lt;70% RH, with battery removed).\u003c\/li\u003e\n\u003cli\u003eTemperature coefficient: 0.1 accuracy\/C (at temperatures \u0026lt;18C or \u0026gt;28C).\u003c\/li\u003e\n\u003cli\u003eOver-range indication: The LCD display will show “OL”.\u003c\/li\u003e\n\u003cli\u003eLow battery indication: When the battery voltage falls below the normal operating\u003c\/li\u003e\n\u003cli\u003e600V CAT. III\u003c\/li\u003e\n\u003cli\u003eInput polarity indication: Automatically displays the “-” symbol.\u003c\/li\u003e\n\u003cli\u003ePower supply: 3.7V lithium battery\u003c\/li\u003e\n\u003cli\u003eDimensions: 280 x 94 x 43 mm\u003c\/li\u003e\n\u003cli\u003eWeight: Approx. 448g (including battery).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eAC Voltage:\u003c\/strong\u003e\u003c\/p\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRANGE\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eRESOLUTION\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eACCURACY\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e6V\u003c\/td\u003e \u003ctd\u003e0.001V\u003c\/td\u003e \u003ctd rowspan=\"2\"\u003e± (0.8% of reading+5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e60V\u003c\/td\u003e \u003ctd\u003e0.01V\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e600V\u003c\/td\u003e \u003ctd\u003e0.1V\u003c\/td\u003e \u003ctd rowspan=\"2\"\u003e± (1.5% of reading+2 digits)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e750V\u003c\/td\u003e \u003ctd\u003e1V\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e2000V\u003c\/td\u003e \u003ctd\u003e1V\u003c\/td\u003e \u003ctd\u003e± (1.8% of reading+3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003eInput impedance: 10 MΏ, Overload protection: 2000 V DC or 2000 V AC (RMS). Maximum input voltage: 2000 V AC (RMS)\u003c\/p\u003e \u003cp\u003eFrequency range: 40 Hz to 1 kHz\u003c\/p\u003e \u003cp\u003eResponse: True RMS. Note: When measuring AC or DC voltages in the low-voltage range, if the test leads are not connected to the circuit under test, the meter may fluctuate; this is normal and is caused by the meter’s high sensitivity. When the probes are connected to the circuit under test, you will obtain the actual measurement value.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e DC Voltage\u003c\/strong\u003e\u003c\/p\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRANGE\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eRESOLUTION\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eACCURACY\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e6V\u003c\/td\u003e \u003ctd\u003e0.001V\u003c\/td\u003e \u003ctd rowspan=\"2\"\u003e± (0.5% of reading+5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e60V\u003c\/td\u003e \u003ctd\u003e0.01V\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e600V\u003c\/td\u003e \u003ctd\u003e0.1V\u003c\/td\u003e \u003ctd rowspan=\"2\"\u003e± (1.0% of reading+2 digits)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e1000V\u003c\/td\u003e \u003ctd\u003e1V\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e2000V\u003c\/td\u003e \u003ctd\u003e1V\u003c\/td\u003e \u003ctd\u003e± (1.2% of reading+3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003eMaximum input voltage: 2000 V DC RMS\u003c\/p\u003e \u003cp\u003eInput impedance: 10 MΩ\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRANGE\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eRESOLUTION\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eACCURACY\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e6nF\u003c\/td\u003e \u003ctd\u003e0.001nF\u003c\/td\u003e \u003ctd\u003e± (4.0% of reading+20 counts)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e60nF\u003c\/td\u003e \u003ctd\u003e0.01nF\u003c\/td\u003e \u003ctd rowspan=\"7\"\u003e\u003cp\u003e± (4.0% of reading+5 digits)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e600nF\u003c\/td\u003e \u003ctd\u003e0.1 nF\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e6µF\u003c\/td\u003e \u003ctd\u003e0.001µF\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e60µF\u003c\/td\u003e \u003ctd\u003e0.01µF\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e600µF\u003c\/td\u003e \u003ctd\u003e0.1 µF\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e6mF\u003c\/td\u003e \u003ctd\u003e0.001mF\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e60mF\u003c\/td\u003e \u003ctd\u003e0.01 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003eOverload Protection:250 V DC\/AC\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eResistance:\u003c\/strong\u003e\u003c\/p\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRANGE\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eRESOLUTION\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eACCURACY\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e600Ω\u003c\/td\u003e \u003ctd\u003e0.1Ω\u003c\/td\u003e \u003ctd rowspan=\"5\"\u003e\u003cp\u003e± (1.2% of reading+3digits)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e6kΩ\u003c\/td\u003e \u003ctd\u003e0.001kΩ\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e60kΩ\u003c\/td\u003e \u003ctd\u003e0.01kΩ\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e600KΩ\u003c\/td\u003e \u003ctd\u003e0.1Ω\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e6MΩ\u003c\/td\u003e \u003ctd\u003e0.001MΩ\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e60MΩ\u003c\/td\u003e \u003ctd\u003e0.01MΩ\u003c\/td\u003e \u003ctd\u003e± (2.0% of reading+5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eAC Current:\u003c\/strong\u003e\u003c\/p\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRANGE\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eRESOLUTION\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eACCURACY\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e600A\u003c\/td\u003e \u003ctd\u003e0.1A\u003c\/td\u003e \u003ctd rowspan=\"2\"\u003e± (3.5% of reading+5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e2000A\u003c\/td\u003e \u003ctd\u003e1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003eMaximum input current: 2000A \/ Frequency range: 50–60 Hz \/ Response: True RMS\u003c\/p\u003e \u003cp\u003e-When measuring AC current, place the conductor to be tested in the centre of the clamp jaws. If not centred, the maximum positional error may increase by 1.5%.\u003c\/p\u003e \u003cp\u003e-On the AC current range, briefly press the INR key to select INRUSH surge current measurement. At this point, power on the electrical device to measure its instantaneous inrush current; surge current measurement is available only on the 2000A range.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDC Current:\u003c\/strong\u003e\u003c\/p\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRANGE\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eRESOLUTION\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eACCURACY\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e600A\u003c\/td\u003e \u003ctd\u003e0.1A\u003c\/td\u003e \u003ctd rowspan=\"2\"\u003e± (3.5% of reading+5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e2000A\u003c\/td\u003e \u003ctd\u003e1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003einput current: 2000A\u003c\/p\u003e \u003cp\u003eDue to the presence of external electromagnetic fields such as the Earth’s, to ensure the accuracy of the measurement reading, press the ZERO key to set the reading to zero. If the reading is still not zero after pressing the key, press it several times until the reading is zero. Note: Due to the high sensitivity of the product, to ensure accurate readings, the orientation of the instrument during measurement should be as consistent as possible with the orientation during zeroing.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003cu\u003e \u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eTemperature Measurement:\u003c\/strong\u003e\u003c\/p\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRANGE\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eRESOLUTION\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eACCURACY\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e-20°С ̴ 1000°С\u003c\/td\u003e \u003ctd rowspan=\"2\"\u003e\u003cp\u003e1FС\/1°С\u003c\/p\u003e\u003c\/td\u003e \u003ctd\u003e± (1.5% of reading+5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e-4°F ̴ 1832°F\u003c\/td\u003e \u003ctd\u003e± (1.5% of reading+10 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003eTemperature specifications do not include thermocouple error.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eClamp-on frequency measurement (via Range A):\u003c\/p\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRANGE\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eRESOLUTION\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eACCURACY\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e1Hz- 2000Hz\u003c\/td\u003e \u003ctd\u003e1Hz\u003c\/td\u003e \u003ctd\u003e± (2.0% of reading+10 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003eMeasurement range: 1 Hz to 2000 Hz\u003c\/p\u003e \u003cp\u003e– Input signal range: 60 A AC (RMS)\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eVia V-range:\u003c\/strong\u003e\u003c\/p\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRANGE\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eRESOLUTION\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eACCURACY\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003e1Hz- 2000Hz\u003c\/td\u003e \u003ctd\u003e1Hz\u003c\/td\u003e \u003ctd\u003e± (2.0% of reading+10 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003e– Measurement range: 1 Hz to 2000 Hz\u003c\/p\u003e \u003cp\u003e– Input signal range: _2 V AC (RMS)\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctions \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003e Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDiode\u003c\/td\u003e \u003ctd\u003eDisplays the approximate forward voltage drop of the diode\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eContinuity\u003c\/td\u003e \u003ctd\u003eIf the resistance under test is less than 50Ω,the built-in buzzer sounds\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eNCV\u003c\/td\u003e \u003ctd\u003eDisplays intensity based on proximity to the power source \u003cp\u003eand emits a beep at different frequencies\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eLIVE\u003c\/td\u003e \u003ctd\u003eWhen testing the live wire, the display shows “—-” and an \u003cp\u003ealarm sounds; the neutral wire shows no reaction\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePower Off\u003c\/td\u003e \u003ctd\u003eThe meter automatically shuts down after 15 minutes \u003cp\u003ewithout signal input\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is a Smart Digital True RMS Clamp Meter with Backlight. This instrument can be used to measure AC\/DC voltage, AC\/DC Current, Resistance, Capacitance, Temperature and other parameters. It is an ideal tool for solar applications.\u003c\/p\u003e\u003ch3\u003eAccessories\u003c\/h3\u003e\u003cp\u003eUser manual, Test lead, Charging Cable, Thermocouple, Cloth Pouch.\u003c\/p\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1058\/7003\/3239\/files\/SMART-DIGITAL-SOLAR-TRUE-RMS-CLAMP-METER-DT4545PRO.pdf?v=1792744643\" target=\"_blank\" rel=\"noopener\"\u003eCatalog (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Mextech","offers":[{"title":"Default Title","offer_id":52809514057944,"sku":null,"price":7434.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0848\/6653\/1544\/files\/digital-solar-true-rms-clamp-meter-dt4545-2026-1.jpg?v=1793815443","url":"https:\/\/mextechin.com\/products\/digital-solar-true-rms-clamp-meter-dt4545","provider":"Mextech Technologies India Private Limited","version":"1.0","type":"link"}