CEM DT-6650 Multifunction Installation Tester
It is designed with an in-built software system and ensures that the safety of electrical installations in domestic, commercial and industrial applications. DT-6650 can ensure that fixed wiring is safe and correctly installed. It’s fast sampling and dual display, clear symbols and...
Taxes included. Free shipping across India.
Key features
It is designed with an in-built software system and ensures that the safety of electrical installations in domestic, commercial and industrial applications. DT-6650 can ensure that fixed wiring is safe and correctly installed. It’s fast sampling and dual display, clear symbols and exceptionally wide viewing angle provides easy and safe readings.
- 3.5” TFT Colour display
- Fast high current loop test
- Variable RCD current mode for customized settings
- PASS/FAIL indication for RCD tests
- Select voltage measurement between L-N, L-PE and N-PE
- Support SD memory and USB and Blue tooth interface
- Internal Memory
- Safe Earth Volt Touchpad detects raised earth voltages >50V indicating potentially dangerous situations
Specification
| Power Source | 12V DC (8 x 1.5V AA Size Alkaline batteries) |
| Battery Life | Average of 15hours |
| CAT Rating | CAT III 600V |
| Protection Classification | Double Insulation |
| Protection Rating | IP65 |
| LCD Display | 320×240 dot matrix |
| Operating Temp | 0°C~ 45°C |
| Relative Humidity | 95% (10°C~ 30°C) Non-condensing 75% (30°C~ 40°C) Non-condensing |
| Storing Temp | -10°C~ 60°C |
| Operating Altitude | 2000m |
| Protective device | 500mA Fast response BS 88 Fuse |
| Dimensions | 10.5cm(L) x 22.5cm(W) x 13cm(H) |
| Weight | 1.56kg |
LOOP Resistance L- PE (Hi-Amp)
| Range (W) | Resolution(W) | Accuracy |
| 0.23 – 9.99 | 0.01 |
±(4% of reading + 4 digits) |
| 10.0 – 99.9 | 0.1 | |
| 100 – 999 | 1 |
Measuring Current : 4.0 A
Range of the Voltage Used : 195V AC – 260V AC (50,60Hz)
L- PE (No Trip)
| Range (W) | Resolution(W) | Accuracy |
| 0.23 – 9.99 | 0.01 |
±(5% of reading + 6 digits) |
| 10.0 – 99.9 | 0.1 | |
| 100 – 999 | 1 |
Measuring Current : < 15mA
Range of the Voltage Used : 195V AC – 260V AC (50,60Hz)
LINE Resistance L- N
| Range (W) | Resolution(W) | Accuracy |
| 0.23 – 9.99 | 0.01 |
±(4% of reading + 4 digits) |
| 10.0 – 99.9 | 0.1 | |
| 100 – 999 | 1 |
Measuring Current : 4.0 A
Range of the Voltage Used : 195V AC – 260V AC (50,60Hz)
RCD (BSEN 61557-6)
Rcd Rating (I_n) :10mA, 30mA, 100mA, 300mA, 500mA and 1A. Test current : x1/2, x1, x2 and x5
Accuracy at applied test current
| Test current | Accuracy |
| x1/2 | ±(1% of reading+ 1 digits) |
| x1 | ±(1% of reading+ 1 digits) |
| x2 | ±(1% of reading+ 1 digits) |
| X5 | ±(1% of reading+ 1 digits) |
Form of the Test Current : Sine wave form (AC), Pulse wave form (DC)
RCD Form : General (G – non-delayed), Selective (S – time-delayed)
Initial Polarity of the Test Current : 0°, 180°
Voltage Range : 195V AC – 260V AC (50Hz,60Hz)
Accuracy of the Timing of the RCD : ± (10% of reading + 1 digits)
Resolution of the RCD Timing : 0.1ms
VOLTAGE AND FREQUENCY
| Measurement Range (V) / AC-DC | Resolution (V) | Accuracy |
| 80 – 500 | 1 | ±(2% of reading + 2digits) |
| Measurement Range (Hz) | Resolution (Hz) | Accuracy |
| 45 – 65 | 1 | ±2Hz |
INSULATION RESISTANCE:
| Terminal Voltage | Range | Resolution | Accuracy | Test Current | Short circuit current |
125V(0%~+10%) | 0.125~4.000 MW | 0.001MW | ±(2%+10) | 1mA @load125kW | £1mA |
| 4.001~40.00 MW | 0.01MW | ±(2%+10) | |||
| 40.01~400.0 MW | 0.1MW | ±(4%+5) | |||
| 400.1~1000 MW | 1MW | ±(5%+5) | |||
250V (0%~+10%) | 0.250~4.000 MW | 0.001MW | ±(2%+10) | 1mA @load250kW | £1mA |
| 4.001~40.00 MW | 0.01MW | ±(2%+10) | |||
| 40.01~400.0 MW | 0.1MW | ±(3%+2) | |||
| 400.1~1000 MW | 1MW | ±(3%+2) | |||
500V(0%~+10%) | 0.500~4.000 MW | 0.001MW | ±(2%+10) | 1mA @load500kW | £1mA |
| 4.001~40.00 MW | 0.01MW | ±(2%+10) | |||
| 40.01~400.0 MW | 0.1MW | ±(3%+2) | |||
| 400.1~1000 MW | 1MW | ±(4%+5) | |||
1000V (0%~+10%) | 1.000~4.000 MW | 0.001MW | ±(3%+10) | 1mA @load1MW | £1mA |
| 4.001~40.00 MW | 0.01MW | ±(2%+10) | |||
| 40.01~400.0 MW | 0.1MW | ±(3%+2) | |||
| 400.1~1000 MW | 1MW | ±(4%+5) |
Low Ohm
| Range | Resolution | Accuracy |
| 0.00~99.99W | 0.01W | +(2%+30d) |
| 100.0~999.9W | 0.1W | +(2%+6d) |
| 1000~2000W | 1W |
Earth Resistance:
| Range | Resolution | Accuracy | Max. open Circuit Voltage | Overload Protection |
| 0.000~2.000W | 0.001W | +(1.5%+30) | 5.0V | 250Vrms |
| 2.00~20.00W | 0.01W | +(1.5%+3) |
||
| 20.0 ~200.0W | 0.1W | |||
| 200 ~2000W | 1W | +(1.5%+5) |
Applications
It is designed with an in-built software system and ensures that the safety of electrical installations in domestic, commercial and industrial applications.
DT-6650 can ensure that fixed wiring is safe and correctly installed. It’s fast sampling and dual display, clear symbols and exceptionally wide viewing angle provides easy and safe readings.
Accessories
- ACCESSORIES: Carrying Case
- Test Leads
- Test Cut
- Instruction Manual
- Battery
- Test Certificate
CEM DT-6650 Multifunction Installation Tester