Digital Earth Clamp Tester

Home > Product > Digital Earth Clamp Tester > DIGITAL EARTH CLAMP TESTER DECT9+

DIGITAL EARTH CLAMP TESTER DECT9+

Introduction

Get a Quote
  • Features
  • Specification
  • Applications
  • Accessories
  • Download
  • Long Jaw size: 65mm x 32mm. The unique long Jaw is particularly suitable where grounding is done by flat steel or copper strips.
  • Range:0.01Ω to 1500 Ω, leakage current: 0.00mA to 30A
  • Maximum Resistance Measurement Resolution 0.001 Ω.
  • Display 4 Digits LCD, 47×28.5 mm in length.
  • USB Communication Port
  • Over range (OL Ω) as well as low range (L0.01 Ω) indication.
  • Low bat indication and Data hold facility, Jaw opening Indication, Noise signal
  • Double insulation level and also protected from External magnetic as well as Electric field.
  • External Magnetic field: <40A/m
  • External Magnetic field: <1V/m
  • Automatic range selection & Automatic Self Calibration.
  • Alarm with measured value
  • Single Measuring Time: 0.5 second.
  • Data Storage : 99 Groups
  • Clamp Jaw opening Size : 32mm
  • Setting Range of Resistance Alarm Critical Value : 1-199 Ω
  • Setting Range of Current Alarm Critical Value : 1-499mA
  • Operating Temperature: -10˚C to 55˚C
  • Power: 6 VDC (AA 1.5V x 4)
  • Dimensions : 285mm X 85mm X 56mm
  • Weight: 1100gms (including Batteries).

SPECIFICATION:

 

Ranges and Accuracy at [ (20 ±3˚C) 50% RH ± 10%]

Ranges Resolution Accuracy
0.010 – 0.099Ω 0.001Ω ±(1%+0.01Ω)
0.10 – 0.99Ω 0.01Ω ± (1% + 0.01Ω)
1.0 -49.9Ω 0.01Ω ± (1.0% + 0.1Ω)
50.0 – 99.5Ω 0.5Ω ± (1.5% + 0.5Ω)
100-199Ω 1Ω ± (2% + 1Ω)
200- 395Ω 5Ω ± (5% + 5Ω)
400- 590 Ω 10 Ω ± (10% + 10Ω)
600 – 880 Ω 20 Ω ± (20% + 20Ω)
900 – 1500 Ω 30 Ω ± (25% + 30Ω)

 

 

Ranges and Accuracy of current measurement:

Range Resolution Accuracy
0.00mA-9.95mA 0.05mA ±2.5%+1mA
10mA-99mA 0.1mA ±2.5%+5mA
100mA-300mA 1mA ±2.5%+10mA
0.30A-2.99A 0.01A ±2.5%+0.1A
3.0A-9.9A 0.1A ±2.5%+0.3A
10A-20A 0.1A ±2.5%+0.5A
10A-30A 0.1A ±3.0%+1A

 

Digital earth Clamp Tester is applicable to use in the grounding Resistance measurement of the Power, Telecommunications, Meteorology, oilfield, construction and the industrial and electrical equipment.

      The tester can measure leakage current grounding system and the neutral Current.

  • Accessories: Carrying Case, Standard Loop Resistance of 5.1Ω, Instruction Manual, Batteries, USB Communication, Cable and Software.
COPYRIGHTS © 2024. ALL RIGHTS RESERVED | Website Designed by Dynasoft

    Get a Quote