Home > Product > DIGITAL INSULATION TESTER DIT99C

DIGITAL INSULATION TESTER DIT99C

Introduction

Mextech’s DIT99C is a high-quality multi-range insulation tester, featuring a large backlight display.

Get a Quote
  • Features
  • Specification
  • Applications
  • Accessories
  • Download
  • CPU controlled, simple operation
  • Rated Voltage: 250V, 500V, 1000V
  • Auto data hold
  • High voltage output automatically delay for 30s
  • Fault protection, buzzer alarms if short circuit.
  • General Specifications:
  • Display: 80*60mm LCD
  • Max reading: 1999 counts
  • Power: 4*1.5V Batteries
  • Low Battery : Low Battery sigh on LCD
  • Overload Indication: LCD displays “1”
  • Static consumption: about 1.0mA, Short circuit current > 1.7mA
  • Operation Environment: Temperature: 0˚C – 40˚C; Humidity:30% -80% RH
  • Storage Environment: Temperature: -10˚C – 50˚C; Humidity <85%RH
  • Powered Supply: a) 4 X 1.5V batteries.
  1. b) External Power Supply
  • Dimension: 140 x 100 x 48 mm
  • Weight: 500g including Batteries
Voltage Range MeasurementRange Resolution Medium Resistance Accuracy
250V 200MΩ 2MΩ~200MΩ 0.1MΩ 2MΩ ±(5%+5)
500V 1000MΩ 20MΩ~1000MΩ 1MΩ 20MΩ ±(4%+5)
1000V 2000MΩ 20MΩ~2000MΩ 1MΩ 20MΩ ±(5%+5)
Voltage Test Range : AC: 30V ~ 750V ;              Accuracy : ±2%rdg±5V

 

OPERATION 

  • Connect input terminal E To GND of test subject. Connect terminal L to test circuit. (Hang terminal L as much as possible. When testing cable, connect COM terminal to GND)
  • PUSH the switch to “TEST” to turn ON the unit. LCD displays “1” (NOTE: When LCD displays change the batteries.)
  • When press “TEST”, there is high voltage output at terminal “L” and “E”, (Press “TEST” again to stop data hold and return to normal status)
  • If LCD display “1” after “TEST” there are two possibilities:
  • The measured resistance may exceed the maximum range.
  • The unit is connected to a open circuit.
  • Note : When press “TEST”, there are high voltage output at “L” and “E”. DO NOT touch the subject resistance or disconnect test leads. The reading may flash but a stable reading or “1” will display.
  • If no stable reading is shown, there are four possibilities:
  • Connecting cable is too long.
  • The humidity of the test environment is higher than standard.
  • The outer layer of the subject resistance must connect to “COM”
  • The subject resistance is not stable or in a critical state.

Mextech’s DIT99C is a high-quality multi-range insulation tester, featuring a large backlight display.

Instructional manual, 4 Nos. AA Batteries, Test Leads.

COPYRIGHTS © 2026. ALL RIGHTS RESERVED | Website Designed by Dynasoft