Oscilloscope

Home > Product > Oscilloscope > OSCILLOSCOPE OS5020C

OSCILLOSCOPE OS5020C

Introduction

This 20MHZ OS 5020 Dual Trace Oscilloscope with component Test has been widely used in the fields of teaching, enterprises, scientific Research and medical Treatment

Get a Quote
  • Features
  • Specification
  • Applications
  • Accessories
  • Download
  • Component Test
  • Power supply: AC 220V/50HZ
  • Dimension: 310x145x440mm (W X H X D)
  • Operating temperature: 0~40°C 85% RH
  • Storage Temperature: -10~70°C
  • Weight: About 8kgs

Accessories: Instruction manual, 1m AC supply Power wire, 2ms probes, Probe for component Test

  SPECIFICATION:

Sensitivity 5mV-20V/DIV in 1-2-5 sequence, altogether 12 steps, CH1, CH2 to 1mV/DIV with x5 magnification.
Accuracy X1: ≤±3%, x5MAG: ≤±5%,
Variable Ratio ≥2.5:1
Bandwidth(-3dB) x1: DC(AC10Hz)~20MHz,

x5: DC(AC10Hz) )~7MHz,

Rising Time x1: ≤17.5ns, x5: ≤50ns
Input Impedance 1MΩ±5% // 25pF±5pF
DC Balance 5mV-20V/DIV: ±0.5DIV
Linearity The amplitude change would be within±0.1V when the waveform moves vertically in the middle of the Division.
Vertical Mode CH1, CH2, ALT, CHOP, ADD(CH1+CH2, CH1-CH2)
Input Coupling AC, GND, DC
Max. Input Voltage 400V with the frequency ≤ 1kHz

Max. Effective readout would be 160Vp-p(56Vrms sine wave) when the probe is set as1:1.

Max. Effective readout would be 400Vp-p(140Vrms sine wave) when the probe is set as 10:1.

CH2 INV BAL ≤1DIV

 

 

Trigger Sources INT, EXT, LINE
INT Trigger Source CH1, CH2, VERT.
Trigger Modes NORM, AUTO(TV-H), TV-V, LEVEL LOCK.
Coupling AC: 5Hz to the whole frequency range
Polarity +/-
Sensitivity INT: 5Hz-10MHz ≤ 1DIV; 10MHz-20MHz ≤ 1.5 DIV; TV: ≤2DIV
EXT: 5Hz-10MHz ≤ 200mVp-p; 10MHz-20MHz ≤ 300mVp-p
Input impedance with EXT trigger signals Max Input Voltage 1MΩ±5%//25pF±5pF

400V(DC+A Cpeak) AC frequency:≤1kHz

Sweep time 0.5s-0.2us/DIV, in 1-2-5 sequence, altogether 20 steps
Accuracy x1: ≤±3%; 10MAG; ≤±5%(20ns~50ns :±10%)
Variable Ratio ≥2.5:1
Linearity x1:5%; x10MAG: 10%(20NS~50NS : 15%)
Movement by x10 MAG <2DIV in CRT center

 

      

X-Y Mode Sensitivity Same the vertical systems
Frequency Bandwidth(-3dB) DC: 0~500kHz; AC: 10Hz~500kHz
X-Y Phase Difference ≤3֯(DC-50kHz)
Calibration Signal Waveform Square wave
Frequency Approx. 1kHz
Output Voltage 2Vp-p±2%
Output Resistance Approx. 1kΩ
CRT Model 15SJ118Y14
Color & Afterglow Green, middle
Effective Screen Area 8 X 10DIV[1DIV=10mm(0.39in)]
Scale Internal
Trace Rotation Adjustable on Panel

This 20MHZ OS 5020 Dual Trace Oscilloscope with component Test has been widely used in the fields of teaching, enterprises, scientific Research and medical Treatment

  • Accessories: Instruction manual, 1m AC supply Power wire, 2ms probes, Probe for component Test.
COPYRIGHTS © 2024. ALL RIGHTS RESERVED | Website Designed by Dynasoft

    Get a Quote